+86 137 3547 3998
Home / Sterilizer / Ethylene Oxide Sterilization Equipment
Ethylene Oxide Sterilization Equipment
Ethylene Oxide Sterilization Equipment
Ethylene Oxide Sterilization Equipment
Ethylene Oxide Sterilization Equipment
Ethylene Oxide Sterilization Equipment

Ethylene Oxide Sterilization Equipment

The Industrial Ethylene Oxide sterilizers are welded by stainless steel and a heating water jacket. The materials of the inner tank are stainless steel 304, Thicknessδ=6mm
The regular standard size of our Industrial Ethylene Oxide sterilizers, We can also offer customized sizes if you need them. 

click here for the details.

Share
Paramter

 Product-related Dimensions

SPECIFICATIONS

OUTSIDE SIZE mm

TRANSPORT SIZE mm

INSIDE SIZE mm

NET VOLUMm³

FST-(50-100)

Designed according to users

50-100

 

FST-40

 

13000X3100X4100

 

13000X2050X3100

 

12500X1500X2200

 

41.25

FST-35

11500X3100X4100

11500X2050X3100

11000X1500X2200

36.3

FST-30

11500X2950X3900

11500X1900X2900

11000X1350X2050

30.44

FST-25

10000X2950X3800

10000X1900X2800

9500X1350X1950

25.01

FST-20

9450X2950X2875

9450X1900X2400

9000X1350X1700

20.655

FST-15

7200X2950X2875

7200X1900X2400

6750X1350X1700

15.491

FST-10

4950X2950X2875

4950X1900X2400

4500X1350X1700

10.328

FST-06

3250X2950X2875

3250X1900X2400

2800X1350X1700

6.426

FST-03

2300X2300X2700

2300X1550X2350

1850X1000X1670

3.089

FST-01

1750X1700X1750

1750X1700X1750

1500X700X1000

1.05

 

Product Details:

The industrial ethylene oxide sterilization equipment is an efficient and professional medical equipment sterilization tool. It uses ethylene oxide as the sterilization medium and uses its high-efficiency killing ability under appropriate conditions to completely remove microorganisms on the surface of medical devices, including bacteria, viruses and fungi, ensuring the sterility of the devices.
The sterilizer is well designed and equipped with advanced control systems and monitoring equipment, which can accurately control the temperature, humidity and ethylene oxide concentration during the sterilization process, thereby ensuring the consistency and reliability of the sterilization effect. At the same time, it also has a high degree of safety and stability, and is equipped with multiple safety protection measures to effectively prevent ethylene oxide leakage and accidents.
Industrial ethylene oxide sterilizers also have the advantages of easy operation and convenient maintenance. They can adapt to various complex sterilization needs and are indispensable and important equipment in the fields of medical care, scientific research, pharmaceuticals and other fields. Whether it is a large hospital or a small clinic, this sterilizer can be used to achieve efficient and safe instrument sterilization to protect the health of patients.
FIRSTEO Machinery
Equipment Co., Ltd.

FIRSTEO Machinery Equipment Co., Ltd. is one of the well-known China Ethylene Oxide Sterilization Equipment manufacturers and Ethylene Oxide Sterilization Equipment suppliers in China. We have our own technology development, design, production, sales and service department. Our products include the overall facilities of the ethylene oxide sterilization workshop, the pretreatment room, the ethylene oxide sterilizer, the analytical room and the ethylene oxide waste gas treat equipment. Our company has established in a quality management system which accordance with ISO9001:2008 and ENISO134585:2003/AC2009. Our company is engaged in: pretreatment - sterilizer - strong analytical --EO waste gas treatment, the whole process equipment manufacturing factory to provide custom Ethylene Oxide Sterilization Equipment and wholesale Ethylene Oxide Sterilization Equipment. We are a famous China Ethylene Oxide Sterilization Equipment suppliers and Ethylene Oxide Sterilization Equipment factory of ethylene oxide sterilization that uses hot air heating system in China, and had applied the "utility model patent certificate" (energy saving, water-saving, no corrosion, fast heating speed; which can extend the life of the equipment for 10-15 years). Our own FSTEO-WQ series of ethylene oxide waste air absorption and treatment equipment was developed with the domestic universities. It allows the low temperature reaction process and reselected the catalyst reacting under low temperature. The removal rate of the waste gas was more than 99.9% after the purification of the waste gas. The emission residual gas is far below the national standard requirements. We have also developed an automatic control system which can join the operation between the waste gas treat process and the sterilizing cabinet. Our technical engineers have decades of experience in the industry. So we can provide professional man to install, test, training or repair machine for customer. We have a large number of high-quality customers: Jiangsu Fresenius Medical Care (Germany), Nanchang Kelinnike Medical Appliance (Germany), Shenzhen DooJung Group (Korea), Nanjing micro-tech, Winner Medical and other well-known Pharmaceutical equipment or other related products enterprises in China. We can also provide you with the best equipment and services.

Customer Evaluation
l am very happy with everything and I want to congratulate you for an outstanding worker
l am very happy with everything and I want to congratulate you for an outstanding worker
l am very happy with everything and I want to congratulate you for an outstanding worker
l am very happy with everything and I want to congratulate you for an outstanding worker
you deserve it as you are excellent at your job and help me timeously with all my problems.
Leave a Message
If you have any questions, please leave us a message and we will reply to you as soon as possible
  • Name *
  • Email *
  • Country *
  • Telephone
  • Message *
  • Honor
    HO
    Business license
    HO
    Patent certificate
    HO
    Production License

    FIRSTEO
    Machinery News

    Industry knowledge

    What are the key components and features of a sterilization chamber used in the medical industry?

    Chamber Body: The main body of the sterilization chamber is typically made of stainless steel or other durable materials that can withstand high temperatures and pressure. It is designed to provide a sealed and controlled environment for the sterilization process.
    Door and Locking Mechanism: The chamber is equipped with a secure door that allows easy loading and unloading of items while maintaining a tight seal during the sterilization process. The door is often equipped with a locking mechanism to prevent unauthorized access and ensure safety.
    Heating System: Sterilization chambers utilize a heating system, such as electric or steam heating, to achieve the desired sterilization temperature. The heating system ensures that the chamber reaches and maintains the required temperature for effective sterilization.
    Control Panel: The control panel is an essential feature of a sterilization chamber, allowing the user to set and monitor various parameters such as temperature, pressure, sterilization cycle duration, and other relevant settings. It provides the necessary controls and feedback to ensure the sterilization process is carried out accurately.
    Ventilation System: A ventilation system is incorporated into the sterilization chamber to facilitate the removal of air and ensure proper circulation of the sterilizing agent (e.g., steam, ethylene oxide) throughout the chamber. It helps maintain the desired sterilization conditions and promotes even distribution of heat or gas.
    Sterilizing Agent Delivery System: Depending on the sterilization method used, the chamber may include a system for delivering the sterilizing agent, such as steam, hydrogen peroxide, or ethylene oxide, into the chamber. This system ensures the proper introduction and distribution of the sterilizing agent for effective sterilization.
    Safety Features: Sterilization chambers are equipped with various safety features to protect both the operator and the items being sterilized. These features may include pressure relief valves, temperature sensors, alarms, interlocks, and emergency stop buttons to prevent accidents or system failures.
    Monitoring and Recording Systems: Many sterilization chambers are equipped with monitoring and recording systems that track and log critical parameters such as temperature, pressure, exposure time, and other relevant data. These systems help ensure compliance with regulatory requirements and provide documentation for quality control purposes.
    Filtration System: Some sterilization chambers incorporate filtration systems to remove impurities or particulate matter from the sterilizing agent or the chamber environment, enhancing the sterility assurance level.
    Documentation and Traceability: Sterilization chambers may have features to facilitate documentation and traceability, such as built-in printers, barcode scanners, or data logging capabilities. These features aid in the proper identification and tracking of sterilized items, contributing to inventory management and quality control processes.

    How does the sterilization process in a chamber differ from other sterilization methods?

    Sterilizing Agent: Different sterilization methods utilize various sterilizing agents. In a chamber-based sterilization process, common sterilizing agents include steam, ethylene oxide (ETO), hydrogen peroxide, or a combination of these. Other sterilization methods may employ different agents, such as dry heat, radiation (e.g., gamma or electron beam), or chemical solutions (e.g., glutaraldehyde).
    Sterilization Mechanism: The mechanism by which sterilization is achieved can vary. In a chamber-based sterilization process, steam or other sterilizing agents are introduced into a sealed chamber, creating a controlled environment. The combination of heat, pressure, and exposure time ensures the destruction or inactivation of microorganisms. Other methods may rely on different mechanisms such as heat conduction (dry heat), oxidative reactions (ETO or hydrogen peroxide), or denaturation of proteins (radiation).
    Equipment and Chamber Design: The equipment used in chamber-based sterilization processes is specifically designed to accommodate the particular sterilization method. For example, a steam sterilization chamber will have features such as heating elements, pressure control mechanisms, and a system for generating and distributing steam. Other sterilization methods may require different equipment, such as dry heat ovens, radiation chambers, or specialized equipment for chemical sterilization.
    Compatibility with Items: Different sterilization methods have varying compatibility with different types of items. Chamber-based sterilization methods, such as steam or ETO, are generally suitable for a wide range of medical devices and instruments, including heat and moisture-resistant materials. However, some items may be sensitive to high temperatures, moisture, or certain chemicals, necessitating the use of alternative sterilization methods that are more compatible with their specific requirements.
    Penetration and Cycle Time: The ability of the sterilizing agent to penetrate different materials and achieve sterilization can vary among methods. Steam, for example, has excellent penetration abilities and can effectively sterilize porous items. Other methods, such as dry heat or radiation, may have limitations in penetrating certain materials. Additionally, the cycle time required for sterilization can differ. Some methods, such as ETO, may require longer exposure times to ensure thorough sterilization.
    Environmental Considerations: Each sterilization method has its own environmental considerations. Chamber-based sterilization methods that utilize steam or other agents may require adequate ventilation or exhaust systems to remove residual gases or moisture after the sterilization process. Other methods, such as radiation sterilization, may have specific requirements for shielding and safety measures to protect operators and the environment.
    Regulatory Requirements: Different sterilization methods may have specific regulatory requirements and guidelines that need to be followed. Standards and regulations can vary depending on the method and the industry. It is crucial to adhere to these requirements to ensure the safety and effectiveness of the sterilization process and comply with industry regulations.